Concurrent Determination of Reliability and Validity of Force Platform, Danesh Salar-e Iranian, Using Kistler's Platform in Measuring Static Balance of Men and Women Athletes; A Descriptive-Surveying Study

Document Type : Original Articles

Authors

1 MSc Student, Department of Physical Education and Sport Sciences, School of Physical Education and Sport Sciences, Isfahan (Khorasgan) Branch, Islamic Azad University, Isfahan, Iran

2 Associate Professor, Department of Physical Education and Sport Sciences, School of Physical Education and Sport Sciences, Isfahan (Khorasgan) Branch, Islamic Azad University, Isfahan, Iran

3 Associate Professor, Department of Prosthetics and Orthotics, School of Rehabilitation Sciences AND Musculoskeletal Research Center, Isfahan university of Medical Science, Isfahan, Iran

10.22122/jrrs.v14i6.3377

Abstract

Introduction: The aim of the current research was to concurrently determine the reliability and validity of force platform device, Danesh Salar-e Iranian, using Kistler's platform device in measuring the static balance of men and women athletes.Materials and Methods: Participants consisted of 50 athletes (25 men and 25 women) from Isfahan City, Iran, who were selected using a purposive convenience sampling method. The research instrument included the force platform device of Danesh Salar-e Iranian model and Kistler's platform device. The subjects tried to keep their static balance on each of the force platforms for 40 seconds with eyes open and eyes closed. After 48-72 hours, test-retest was done under the same conditions as the first test. Each test repeated three times. To measure internal and time reliability, the within-group and between-group correlation tests were used. To measure the concurrent validity, the Pearson correlation test was used. The significance level was set at P < 0.05. Results: Kistler's platform had internal reliability in all open- and closed-eyes parameters; while the Danesh Salar-e Iranian force platform had internal reliability in all closed-eyes parameters. Both the force platform deviceshad time stability in all open-eyes parameters. Kistler's platform had time stability in all closed-eyes parameters (except total oscillation), too. In addition, there was a significant correlation in all variables between the two force platform devices.Conclusion: Danesh Salar-e Iranian force platform is a valid and reliable equipment to measure the static balance in men and women athletes in most parameters. Technical improvements of the equioment can increase the psychometric parameters of this tool, as well as its usability and effectiveness. This can promote national production, and pave the way for economic growth, national efficiency, and emancipation of dependency.

Keywords

  1. Ricotti L, Ravaschio A. Break dance significantly increases static balance in 9 years-old soccer players. Gait Posture 2011; 33(3): 462-5.
  2. Kitago T, Krakauer JW. Motor learning principles for neurorehabilitation. Handb Clin Neurol 2013; 110: 93-103.
  3. Schneiders AG, Sullivan SJ, Gray AR, Hammond-Tooke GD, McCrory PR. Normative values for three clinical measures of motor performance used in the neurological assessment of sports concussion. J Sci Med Sport 2010; 13(2): 196-201.
  4. Langley FA, Mackintosh SFH. Functional balance assessment of older community dwelling adults: A systematic review of the literature. Internet Journal of Allied Health Sciences and Practice 2007; 5(4): 1-11.
  5. Villamonte R, Vehrs PR, Feland JB, Johnson AW, Seeley MK, Eggett D. Reliability of 16 balance tests in individuals with Down syndrome. Percept Mot Skills 2010; 111(2): 530-42.
  6. Meshkati Z, Namazizadeh M, Salavati M, Meshkati L. The Comparison of the role of vision on static postural stability in athletes and nonathletes. Iran Rehabil J 2010; 8(1): 50-3.
  7. Jancova J. Measuring the balance control system--review. Acta Medica (Hradec Kralove) 2008; 51(3): 129-37.
  8. Ottenbacher KJ, Tomchek SD. Reliability analysis in therapeutic research: Practice and procedures. Am J Occup Ther 1993; 47(1): 10-6.
  9. Walter SD, Eliasziw M, Donner A. Sample size and optimal designs for reliability studies. Stat Med 1998; 17(1): 101-10.
  10. Shieh G. Optimal sample sizes for the design of reliability studies: Power consideration. Behav Res Methods 2014; 46(3): 772-85.
  11. Meshkati Z, Namazizadeh M, Salavati M, Mazaheri M. Reliability of force-platform measures of postural sway and expertise-related differences. J Sport Rehabil 2011; 20(4): 442-56.
  12. Akbari M, Farahini H, Faghihzadeh S. An investigation of static and dynamic determinants of balance problems in grade I and II traumatic unilateral lateral ankle sprains using clinical and Modares J Med Sci Pathol 2004; 6(2): 23-32. [In Persian].
  13. Torres-Oviedo G, Ting LH. Muscle synergies characterizing human postural responses. J Neurophysiol 2007; 98(4): 2144-56.
  14. Mohammadbeigi A, Mohammadsalehi N, Aligol M. Validity and reliability of the instruments and types of measurments in health applied researches. J Rafsanjan Univ Med Sci 2015; 13(12): 1153-1170. [In Persian].
  15. Santos BR, Delisle A, Lariviere C, Plamondon A, Imbeau D. Reliability of centre of pressure summary measures of postural steadiness in healthy young adults. Gait Posture 2008; 27(3): 408-15.